1.Bundle模式以bin文件启动交换机,dir检查当前flash中是否有packages.conf文件,可以改名备份或删除
- Switch# dir flash:
- Directory of flash:/
- 7386 -rwx 2097152 Jan 24 2013 +00:00 nvram_config
- 7378 drwx 4096 Jan 24 2013 +00:00 mnt
- 7385 -rw- 221775876 Jan 24 2013 +00:00 cat3k_caa-universalk9.SSA.03.12.02.EZP.150-12.02.EZP.150-12.02.EZP.bin
- 7389 -rwx 556 Jan 21 2013 20:47:30 +00:00 vlan.dat
- 712413184 bytes total (445063168 bytes free)
2.提取package files(包文件)和provisioning file(配置文件 packages.conf)
Switch# software expand running to flash:
3.再次dir flash,查看是否有packages.conf文件
4.设置启动模式为Install模式
Switch(config)# boot system switch all flash:packages.conf
5.保存并重启
- Switch# write memory
- Building configuration...
- Compressed configuration from 4851 bytes to 2187 bytes[OK]
-
- Switch#
- Switch# reload
- Reload command is being issued on Active unit, this will reload the whole stack
- Proceed with reload? [confirm]